Enclosure
The ICSI Temperature and CO2 enclosure maintains a stable and uniform temperature and CO2 concentration all around the ICSI workstation.
Temperature is controlled by recirculating a stream of warm air inside the enclosure. Temperature accuracy is achieved by providing feedback from a temperature sensor placed inside the enclosure. Temperature uniformity is achieved by thanks to dual input / output air channels and by the action of the flow diffusors.
CO2 is controlled by gently infusing CO2 into the enclosure and by measuring gas composition with a Dual Beam Infra Red sensor conveniently placed inside the enclosure.
Ergonomic design allows free access to microinjection joysticks.
Features
- Uniform temperature within the enclosure thanks to dual input / output channels and flow diffusors
- HePa filtering option on request
- Stable CO2 composition, controlled with state of the art infra red CO2 sensors
- Ergonomic design allows easy access to the sample and the microscope
- Micro-manipulator joysticks not enclosed
Temperature Unit
Okolab ICSI T & CO2 ENCLOSURE employs a Temperature Unit that generates warm air to raise the temperature inside the enclosure.
Superior accuracy is guaranteed by the interplay of three sensors: two for temperature and one for flow rate. The temperature sensors monitor temperature inside the enclosure and inside the Air Heater. The flow rate sensor controls the rate at which warm air enters the enclosure and ensures smooth operation and fast heating. A proprietary smart algorithm determines the minimum flow rate necessary to maintain the controlled temperature at the set point value.
Features
- Temperature range: from 3°C above ambient to 45°C
- Temperature accuracy: 0.1°C
- # 2 Temperature sensors: in the enclosure and inside the air heater
- # 1 Flow rate sensor inside the air heater
- Operated via touch screen interface OKO-TOUCH
- Double air input and output with flow diffusors ensures best temperature uniformity inside the enclosure
- Low energy consumption thanks to warm air recirculation
- HePa Filtering Unit - Optional
- Compatible with SMART BOX data logger - Optional
- Alarm Buzzer and External Alarm Connector
CO2 CONTROLLER
The CO2-CONTROLLER-BL connects to the Temperature Controller via a cable-less connector and is operated through the same touch screen interface OKO-TOUCH.
Features
- CO2 sensor accuracy: 0.1%
- CO2 range: 0-18%
- CO2 sensor: 10 year-life Non Dispersive InfraRed (NDIR) dual wave length detector
- CO2 Sensor calibration routine with external meter or calibration gas
- Set Point Resolution: 0.1%; Repeatability: better than 0.1%
- input: 100% CO2 as input
- Touch Screen Interface - OKO-TOUCH
- Programmable CO2 cycles
- Compatible with SMART BOX for data logging and remote operation - Optional
- Data Logging via OKOLAB Data Log Software - Optional
- Alarm Buzzer and External Alarm Connector
- SDK available for integration in third party software
CO2-O2 CONTROLLER
The CO2-O2-CONTROLLER-BL connects to the Temperature Controller via a cable-less connector and is operated through the same touch screen interface OKO-TOUCH.
Features
- CO2 and O2 sensor accuracy: 0.1%
- CO2 range: 0-18%
- O2 range: 0-21%
- CO2 sensor: 10 year-life Non Dispersive InfraRed (NDIR) dual wave length detector
- O2 sensor: optical sensor. Expected lifetime 5 years
- CO2 Sensor calibration routine with external meter or calibration gas
- O2 sensor: Optical sensor - 5 years lifetime.
- Set Point Resolution: 0.1%; Repeatability: better than 0.1%
- input: 100% CO2 and 100% N2
- Touch Screen Interface - OKO-TOUCH
- Programmable CO2 and O2 cycles
- Compatible with SMART BOX for data logging and remote operation - Optional
- Data Logging via OKOLAB Data Log Software - Optional
- Alarm Buzzer and External Alarm Connector
- SDK available for integration in third party software
OKO-TOUCH
OKO-TOUCH is an intuitive and user-friendly touch screen interface. It connects to any one of the Bold Line Controllers, detects all equipment in the system and displays all functions supported by the equipment detected.
It allows to:
- Turn all Bold Line Controllers on/off
- Define set point values
- Set flow rates of the Temperature Unit
- Set flow rates gas controller
- Define gas cycles of gas controller
- Select sample or enclosure feedback mode
- Display all set points and measured parameters
- Run self calibration procedures