BOLD LINE CO2 - O2 CONTROLLERS
The Bold Line CO2 (and / or O2) are digital controllers are especially designed for Microscope incubators. They connect to the Temperature unit and share the same touch screen interface.
- connect to the T-UNIT of the Cage, Stage Top and Heating and Cooling Microscope Incubators
- connect to Active Humidity Module, to provide humidification
Features
- Touch screen interface: OKO-TOUCH
- CO2 accuracy: 0.1% (see Controller page for more info)
- O2 accuracy: 0.1% (see Controller page for more info)
- Touch Screen Interface - OKO-TOUCH
- Output Flow Rate: adjustable from OKO-TOUCH
- Compatible with Active Humidity Controller
- Programmable CO2 (and /or) O2 cycles
- Compatible with SMART BOX for data logging and remote operation
- Data Logging via OKOLAB Data Log Software
- Compatible with: NIS Elements, Metamorph, Micromanager
Preventing evporation?
Use the best Humidifier on the market: ACTIVE HUMIDITY CONTROLLER
It connects to the Gas Controller and shows up in OKO-TOUCH
Hypoxia and / or Hyperoxia ?
Oxygen control is our pride.
Check out the available solutions in the Controller List
Multiple units ? Be Smart - go central
One controller feeds up to 10 microscope incubators.
Microscopes can be in different rooms.
Available Bold Line Digital Controllers
CO2 | O2 | Accuracy | Outlet P, barg (psi) | |
---|---|---|---|---|
CO2-Unit-BL | 0-18% | - | ±0.1% | 0 |
CO2-Unit-BL-CP2 (multi-user centralized controller) | 0-10% | - | ±0.1% | 1.5 (22) |
O2-Unit-BL [1-20] | - | 1-20% | ±0.1% | 0 |
CO2-O2 Unit-BL [0-10;1-18] | 0-10% | 1-18% | ±0.1% | 0 |
CO2-O2 Unit-BL [0-20;1-95] | 0-20% | 1-95% | ±0.1% | 0 |
CO2-O2 Unit-BL [0-10; 0-1] | 0-10% | 0-1% | ±0.1% | 0 |
CO2 - O2 MANUAL GAS MIXERS
These gas mixers employ accurate floating ball flow meters to mix gas AIR and CO2 streams. The desired gas concentration is achieved by measuring the individual flow rated prior to mixing.
For Hypoxia or Hyperoxia applications, a third flow meter if added to measure N2 or O2 flow rate.
No feedback is present on gas concentration.
Features
- 2GF-MIXER mixes AIR with 100% CO2
- CO2 range: 0-15%; accuracy ±1%
- 3GF-MIXER-HYPOXIA mixes AIR, CO2 and N2
- CO2 range: 0-15%, accuracy ±1%
- O2 range: 2-20%, accuracy ±1%
- 3GF-MIXER-HYPEROXIA mixes AIR, CO2 and O2
- CO2 range: 0-15%, accuracy ±1%
- O2 range: 40-85%, accuracy ±1%
- Filtering device: PTFE membrane with 0.2 mm pores
- Compatible with OKO-AP, if compresses air is not available
- For Humidity Control, add Vibration Free Humidity Module
- Not compatible with Active Humidity Controller
Working with Premixed gas ?
All you need is a single flow meter to regulate the flux
Hypoxia and / or Hyperoxia ?
3GF-MIXER is a simple and cost effective solution also for these application.
No Compressed Air ?
Use AIR-PUMP to feed air into the Manual Gas Mixers
Available Manual Gas Mixers
2GF MIXER | 0-20% | - | 0 |
3GF MIXER-HYPOXIA | 0-15% | 2-20% | 0 |
3GF MIXER-HYPEROXIA | 0-15% | 40-85% | 0 |